438 WIN-PAK User Guide
The ability to view and configure Triggers and
Procedures is an exclusive feature of the PRO-2200
Intelligent Controller.
In response to a panel event [trigger], you can define
a set of actions you want the panel to carry out. The
occurrence of the event triggers the execution of the
procedure.
Triggers and procedures are used to define interlocks
[an action on a point triggered by an action on a
different point]. Assigning points and readers to time
zones is also be done via triggers and procedures on
the PRO-2200 Intelligent Controller.
User triggers are those defined for site-specific
events and actions. System triggers are those created
when points are assigned to interlock definitions.
User triggers can be added, edited, or deleted at any
time from the Triggers and Procedures window of
the PRO-2200 Configuration dialogs. System triggers
can be viewed, but not edited from the Triggers and
Procedures window.
When the Triggers and Procedures window is
displayed, system triggers and procedures already
configured for the panel are shown.
Analyzing the system triggers and procedures can
provide great insight into the manner in which
interlocks work in your access control system.
System Triggers and Procedures
System triggers and procedures are created as a result
of an interlock being defined on one of the PRO-
2200 Configuration SIO Board Inputs or Outputs
tabs. Once an action is assigned to an interlock
point, two system triggers and procedures are created
to correspond to the interlock. One trigger and
procedure set deals with the On action, and one
deals with the Off action.